factory technician level - complete with board views :
( removing chassis from cabinet , only thing missing ) ;
on weekends , staff is not available so - be patient .
Excellent manual. In addition to the information I needed was a complete description of both electronic and mechanical devices.
Excellent site.
Thank you very much.
Text excerpt from page 52 (click to view)
SOFTENER DOES NOT FLOW IN
Is water supplied?
NO YES
Refer to ¡ANO WATER SUPPLY¡B Check the wiring on the dispenser.
Wiring diagram
Are receptacles conectly connected to the terminals of inlet valve? NO
YES
Is softener put in the correct compartment of drawer?
MAX
NO
Put it in the correct compartment.
YES
Is the softner cap clogged?
YES
Clean the cap and drawer.
ABNORMAL SOUND
Is the pulley bolt loosened?
YES
Fix the bolt tightly.
NO
Is the belt worn? Replace the V-belt (4400FR3116A)